Nihon Kohden

3-part Diff. Hematology Analyzers

Celltac α+ MEK-1305

CiRHEX Technology

• ESR test results in only 2 min.
• Only 80μL of whole blood required for CBC, 3-part diff. and ESR results.
• Accurate ESR results from a dedicated measurement unit using CBC and aggregated RBC data.
• Does not require any special sedimentation tubes.
• Does not require any special reagents for the ESR test.

Other Features

• 60 tests/hour for CBC+3-part diff.
• ASTM protocol for LIS connection.
• Handy barcode reader operation.
• Operation with Nihon Kohden’s genuine reagents.
• Westgard multirules in QC mode.

DynaHelix Flow Technology

• Sheath flow arranges blood cells in a straight line, and swirling flow pushes cells out and reduces “re-entry” of blood cells that have passed the detection aperture.
Celltac α+ MEK-1305Technical Specifications
21 reportable parametersWBC, LY%, MO%, GR%, LY#, MO#, GR#, RBC, HGB, HCT,
MCV, MCH, MCHC, RDW-CV, RDW-SD,PLT, PCT, MPV, PDW, P-LCR, ESR
11 research parameters(ESR) HCT corr., ESR TEMP corr., SA, AMP, AI, MIN, t1/2
(Others) P-LCC, Mentzer Index, RDWI, NLR
Sample volume CBC with 3-part diff. and ESR: 80 uL
ThroughputCBC with 3-part diff. : 1 min./test 
CBC with 3-part diff. and ESR: 2min./test
Internal memoryMaximum 50,000 data
Dimension/WeightW230 x H450 x D428 mm, approx. 21kg

Celltac α MEK-1301/1302

A choice of two different models, depending on your needs

Celltac α has 2 different models, MEK-1301 and MEK-1302. MEK-1301 has open mode measurement and MEK-1302 has both open and closed mode measurement.
Built-in cap-piercing unit: MEK-1302 has a built-in cap piercing unit that is used in closed mode. This is an important tool  to protect healthcare professionals from infection and ensures operational safety.

MEK-1302
MEK-1301

Features

• Open mode (MEK-1301)
• Open and Closed mode (MEK-1302)
• Enable use of a QC program with Westgard multirules
• Smart ColoRerun Assist system which gives visual notification
• DynaHelix Flow technology for good precision and accuracy

Celltac α MEK 1301/1302Technical Specifications
20 reportable parametersWBC, LY%, MO%, GR%, LY#, MO#, GR#, RBC, HGB, HCT, MCV, MCH,
MCHC, RDW-CV, RDW-SD, PLT, PCT, MPV, PDW, P-LCR
4 research parametersP-LCC, Mentzer Index, RDWI, NLR* (*Neutrophil-to-Lymphocyte Ratio)
Sample volume
(Normal mode)
CBC + WBC 3-part differential: 20 μL
ThroughputApprox. 60 samples/h (open mode)
Internal memoryMaximum 50,000 data
Dimension/WeightW230 x H428 x D450 mm, 20 kg

5-part Diff. Hematology Analyzers

Celltac Es MEK-7300

DynaScatter Laser Technology

• Stain free measurement using laser scattering technology reduces reagent consumption.
• Sheath flow in the measurement path arranges blood cells in a straight line for accurate test results.

Other Features

• Optional handy barcode reader operation
• Optional built-in printer
• Optional LIS connection function
• Provides reliable results through the “ADVANCED COUNT” function for low PLT/WBC samples.
*The image shown here may differ in appearance from the actual product.

Celltac Es MEK-7300Technical Specifications
23 reportable parametersWBC, NE%, LY%, MO%, EO%, BA%,NE#, LY#, MO#, EO#,
BA#, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD,PLT, PCT, PDW, MPV
2 research parametersIG#, IG%
Sample volume CBC : 30uL / CBC+DIFF : 55 uL
ThroughputOpen mode : approx. 60 samples/min.
Dimension/WeightWW382 x H532 x D465 mm, approx. 35kg